Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Calculation of the live load reduction is explained in three four examples which are LiveLoadReductionToType_Example, LiveLoadMaxReduction_Example and LiveLoadReductionDLTest_Example, LiveLoadReductionTransferColumn_Example respectively.

...

Figure 1. LiveLoadReductionToType_Example

...

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1

-5

-10

-15

-5

-10

-15

C2

-5

-9.80

-14.20

-5

-9.80

-14.20

C3

-15

-29.40

-42.60

-15

-29.40

-42.60

C4

-5

-10

-15

-5

-9.80

-14.20

Figure 2. LiveLoadMaxReduction_Example

...

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-24.49

-48.97

-24.49

-48.97

C2

-24.50

-49.01

-24.50

-49.01

C3

-24.50

-49.00

-24.50

-49.00

C4

-24.51

-49.02

-24.51

-49.02

Figure 3. LiveLoadReductionDLTest_Example

...

45.8

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Third Story

Second Story

First Story

Third Story

Second Story

First Story

C1 LL

-9.60

-21.1

-32.5

-9.60

-17.30

-26.06

C1 HLL

-15

-4345.8

-71

-15

-43

-

-73.8

...

73.8

Image Added

Figure 4. LiveLoadReductionTransferColumn_Example

Dimensions : 20ft x 20ft in plan

In this example, column’s tributary area not continuing bottom floors transfers other column’s tributary area.

Live Load Class

Live Load Type

Magnitude, psf

Live Load

75

Reducible Area / Supported Floors

Columns/Reducible Area

Second Story, inch^2

First Story, inch^2

C1

8640

23040

C2

8640

23040

C3

8640

23040

C4

8640

23040

C5

11520

11520

C6

11520

11520

Supported Floors

1

2

Live Load

Column

Fx, kips - Hand Calculation

Fx, kips - Building Design Suite

Second Story

First Story

Second Story

First Story

C1

-4.5

-15

-4.5

-15

C2

-4.5

-15

-4.5

-15

C3

-4.5

-15

-4.5

-15

C4

-4.5

-15

-4.5

-15

C5

-6

0

-6

0

C6

-6

0

-6

0

Verification object link

https://bim.aecbolt.com/platform/?application=inc&author=Verification_Examples_AEC%7CBOLT%2C+Inc&obj=objid7n45xnpgky3bdoogc2jvr