Follow the next steps to set boundary conditions for each bearing location (insertion point) that you have defined while creating the bridge layout.

...

Go to Bearing Fixity on the tree view next to data spreadsheet.

...

Image Removed

...

Set Tx/Ty/Tz/Rx/Ry/Rz.

...

Set Transfer Force to Substructure as Yes for interior pier locations.

...

Set Transfer Force to Substructure as No for start and end support locations.

...

Expand
titleQuick Tip

In this part, dofs are assigned to nodes. The coordinate system of the each insertion point changes along the support line and alignment. According to this new coordinate system, new dofs should be assigned.

Tx/Ty/Tz/Rx/Ry/Rz fixities are shown below.

Image Removed

Bearing Rotation parameter rotates the support clockwise in the XY plane.

Image Removed

FE behaviour of Transfer Force to Substructure.

Image Removed

...

Go to Bearing Fixity under Boundary Conditions on the tree view.

...

Copy Articulation from model inputs and paste into OpenBrIM.

Tip

Completed Bearing Fixity is illustrated below.

...

Info

After clicking on 'Superstructure> Bearings> FEA Bearing' in the navigation treeview, follow the steps to define the bearings. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titleFEA Bearing
FEA Bearing [SIG]
1

🖱️ Click three-dots icon on Insertion Point cell and click Select.

image-20240928-141656.pngImage Added

2

🖱️ Select Insertion Point as a IP1 and Click OK.

Image AddedImage Added
3

Insert excerpt
_Quick Tips
_Quick Tips
nameBearingFixity
nopaneltrue

4

🖱️ Keep the Tx as default.

Image Added
5

🖱️ Click the three-dots icon on the Ty and Tz cell, and then set Fixed.

image-20240928-141745.pngImage Added

6

🖱️ Keep the Rx, Ry, Rz, Bearing Rotation and Transfer Forces to Substructure as default.

image-20240928-141817.pngImage Added

7

🖱️ Keep the bearing’s name as default.

8

When the steps are completed, the shared screenshot displayed in the adjacent cell should be visible in the 3D view of OpenBrIM.

image-20250114-102836.pngImage Added

9

To model all of the bearings, copy the data below and paste the parameters into the first cell in the OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

Insert excerpt
_Quick Tips
_Quick Tips
nameCopyPasteInputs
nopaneltrue

FEA Bearing

Articulation

Code Block
BF1	IP1	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF2	IP2	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF3	IP3	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF4	IP4	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF5	IP5	Fixed	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF6	IP6	Fixed	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF7	IP7	Fixed	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF8	IP8	Fixed	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF9	IP9	Free	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF10	IP10	Free	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF11	IP11	Free	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF12	IP12	Free	Fixed	Fixed	Free	Free	Free	0.0000	YES
BF13	IP13	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF14	IP14	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF15	IP15	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO
BF16	IP16	Free	Fixed	Fixed	Free	Free	Free	0.0000	NO

Anchor
Photo
Photo

Tip

The completed definitions for bearings are illustrated below. Please verify that your model matches by examining each view provided here. For more information on performing visual checks, refer to the quick tips.