After clicking on ‘Substructure Code Checks> Pier Cap Code Check' in the navigation treeview, follow the steps to define the Pier Cap Code Check. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titlePier Cap Code Check
Concrete Pier Cap Code Check [SIG]
1

🖱️ Click the three-dots icon on the Pier Cap cell, and then set PierCap1.

image-20241005-103610.png
2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the code check template, pier cap section, transverse reinforcement profile, and shear reinforcement profile are defined in the next step.

image-20241005-103637.png
3

Insert excerpt
_Quick Tips
_Quick Tips
nameIssue
nopaneltrue

4

🖱️ Click the three-dots icon on the Code Check Template cell, and then set PierCapTemp1.

image-20241005-103732.png

5

🖱️ Change Code Check Loc (Dist. from Right End) to 10.

image-20241005-103911.png

6

🖱️ Keep Design Section w Rebars (or Tendons) as default.

image-20241005-104027.png

7

🖱️ Click three-dots icon on Override Section cell and select a Section as PierCapRec_Mid.

If you have reached this stage and you don't have a section to select, and if you want to use the Import Button, you can refer to the Quick Tip.

image-20241005-104123.pngimage-20241005-104201.png
8

🖱️ Keep Shear Reinforcement Data as default.

image-20241005-104423.png
9

🖱️Select Shear Reinforcement Profile as ASTMA615No5.

🖱️Select Shear Reinforcement Material as A615_60.

image-20241005-104656.png
10

🖱️ Set 6 for Spacing of the Shear Reinforcement.

🖱️ Set 2 for No. of Legs of Shear Reinforcement.

image-20241005-104842.png
11

🖱️ Keep Check For as default.

image-20241005-105132.png
12

🖱️ Set name as PierCapCC1.

image-20241005-105224.png
13

To model all the pier cap code check, copy the data below and paste the parameters into the first cell in OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

Insert excerpt
_Quick Tips
_Quick Tips
nameCopyPasteInputs
nopaneltrue

Pier Cap Code Check

General

Code Block
PierCapCC1	PierCapTemp1	PierCap1	10.0000	Override Section	PierCapRec_Mid	User Input	ASTMA615No5	A615_60	6.0000	2.0000	All
PierCapCC2	PierCapTemp2	PierCap1	10.0000	Override Section	PierCapRec_Mid	User Input	ASTMA615No5	A615_60	6.0000	2.0000	All

Anchor
Photo
Photo

Tip

The completed pier cap code checks are illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

image-20241005-105315.png
Tip

To view the entire procedure explained on this page, please watch the recorded Video below.

SIG EX1 Concrete Pier Cap Code Check.mp4