1 | 🖱️ Click the three-dots icon on the Code Check Template cell, and then set PierFootCCT. | |||||||||||
2 | As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the shear reinforcement profile in longitudinal direction, shear reinforcement profile in transverse direction and shear reinforcement material are defined in the next step. | |||||||||||
3 |
| |||||||||||
4 | 🖱️ Click the three-dots icon on theSelect Pier Footing cell, and then set Footing1. | |||||||||||
5 | 🖱️ Enter the Distance in Longitudinal direction from centroid Code Check Location (Dist. in Long. Dir. from Cent.) as 10. | |||||||||||
6 | 🖱️ Enter the Distance in Transverse direction from centroid Code Check Location (Dist. in Trans. Dir. from Cent.) as 20. | |||||||||||
7 | 🖱️ Keep the Check for For as default. | |||||||||||
8 | You can edit the Flexural Reinforcement parameters of Pier Footing Code Check from Flexural Reinforcement tab. 🖱️ Click the three-dots icon on the Reinforcement Material cell, and then set A615_60. | |||||||||||
9 | 🖱️ Click three-dots icon on the Longitudinal Direction Reinforcement cell and click Edit. | |||||||||||
10 | 🖱️ Please set the following values sequentially: 1st row - Top or Bottom: Bottom Rebar Profile: ASTMA615No8 Spacing of Reinforcement: 10 Distance to Extreme Fiber: 4 | |||||||||||
11 | 🖱️ Click three-dots icon on the Transverse Direction Reinforcement cell and click Edit. | |||||||||||
12 | 🖱️ Please set the following values sequentially: 1st row - Top or Bottom: Bottom Rebar Profile: ASTMA615No8 Spacing of Reinforcement: 10 Distance to Extreme Fiber: 4 | |||||||||||
13 | You can edit the Shear Reinforcement parameters of Pier Footing Code Check from Shear Reinforcement tab. 🖱️ Click the three-dots icon on the Shear Reinforcement Profile in Longitudinal direction cell, and then set ASTMA615No5. | |||||||||||
14 | 🖱️ Click the three-dots icon on the Shear Reinforcement Profile in Transverse direction cell, and then set ASTMA615No5. | |||||||||||
15 | 🖱️ Click the three-dots icon on the Shear Reinforcement Material cell, and then set A615_60. | |||||||||||
16 | 🖱️ Keep the Spacing in Longitudinal directionDirection, Spacing in Transverse directionDirection, No. of Legs in Longitudinal directionDirection, No. of Legs in Transverse direction Direction and Shear Reinforcement as default. | |||||||||||
17 | 🖱️ Set name as PierFootCC. | |||||||||||
18 | Proceed to the next step to verify the model. |
...
Tip |
---|