Please follow the instructions provided below to create Steel Tub Girder code check (according to AASHTO).

1

In this section, you can specify the Tub Girder that you want to be checked it, the station at which you want to be checked it and the code content that you want to perform for it.
This information is necessary for performing code checks.

2

Navigate to Superstructure Code Checks > Steel Tub Girder Code Check (AASHTO)

Image Added

3

Click three-dots icon on Girder and set G1 and G2.

One of the girders will be subjected to constructibility code check template while the other will undergo service code check template.

4

Enter Station [ft] value as 100 both them.

Image Added
5

Additionally, click three-dots icon on Code Check Template and set code check as in the figure.

6

Keep other parameter constant as defult value.

Image Added

7

Navigate Reinforcement tab.

Click three-dots icon on Input Data Preference and set “Lumped”.

Image Added
8

Set deck rebar material to A615_60 both them.

Image Added

9

Enter "Lumped Reinforcement" parameters specified in the corresponding cells as in the figure.

(Note that based on the input data preference, inputs not applicable automatically turns into N/A).

Image Added

10

You can make adjustments to the "Stiffener" tab if you wish.

Image Added

...

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
nameCopyPaste
nopaneltrue

1

Navigate to Steel Tub Girder Code Check (AASHTO) under Superstructure Code Checks on the tree view.

2

Copy General, Reinforcement, and Stiffener from model inputs and paste into OpenBrIM.

Tip

The Steel Tub Girder Code Check (AASHTO) have been created.

...

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
namePasteTip
nopaneltrue

Steel Tub Girder Code Check (AASHTO)

General

Reinforcement

Stiffener

Code Block
languagexml
STGCC1	G1	100	STGTemp_Srv	InteriorPanel	50
STGCC2	G2	100	STGTemp_Cons	InteriorPanel	50
Code Block
languagexml
STGCC1	Lumped	A615_60	8	3	4	3	0	0	NULL	NULL	NULL	NULL	0	0	1
STGCC2	Lumped	A615_60	8	3	4	3	0	0	NULL	NULL	NULL	NULL	0	0	1
Code Block
languagexml
STGCC1	NO	5	1	YES	Use Cross Frame Spacing	82	NO	NULL	50