Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

AEC | BOLT Building Design Suite library object creates 12 force sets for 4 load cases to implement the variations of each load case. The flow of the wind force report document is shown in Figure 2

...

Figure 2

Table of Force Sets

Sets

Wind Direction

ex

ey

Set 1

X

0

0

Set 2

Y

0

0

Set 3

X

0.15 Bx

0

Set 4

X

-0.15 Bx

0

Set 5

Y

0

0.15 By

Set 6

Y

0

-0.15 By

Set 7

X, Y

0

0

Set 8

X, -Y

0

0

Set 9

X, Y

0.15 Bx

0.15 By

Set 10

X, Y

-0.15 Bx

-0.15 By

Set 11

X, -Y

0.15 Bx

0.15 By

Set 12

X, -Y

-0.15 Bx

-0.15 By