Excerpt | ||
---|---|---|
| ||
Point loads on the pile’s top nodes can be applied to piles at the specified stage based on the definitions of the parameters listed below. InputsPile Cap : Choose the pile cap to impose the nodal load on the top node of all piles. Individual Piles : Select individual piles to apply the nodal load on their top node. Stage : Select a stage to apply the load. Fx: Force in the X direction . The longitudinal direction along the alignment will correspond to the X directionwith respect to the element's local axis chosen as the pile cap. Fy: Force in the Y direction . The transverse direction along the alignment will correspond to the X directionwith respect to the local axis of the chosen pile cap. Fz (Gravity): A positive value indicates that the load is applied Force in the direction of gravity, while a negative value indicates that the load is applied in the opposite direction-Z or gravity direction with respect to the chosen element's local axis. Mx: Moment in the longitudinal direction along the PGLpile cap's local X axis. My: Moment in the direction perpendicular to the PGLpile cap's local Y axis. Mz: Moment in the vertical direction with respect to the pile cap's local axis.
|