Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Excerpt
nameStage: Choose the stage for constructing the piers. Usually, the construction of pier caps, piers, footings, and piles is completed within a single stage. Columns: Choose the pier columns for construction. Self Weight Factor: Indicate the self-weight factor, which is calculated using the material's unit weight and the object's volume, typically set to 1.

Pier Column Bracing Construction

Stage: Select the construction stage for the column bracings.

Bracing: Choose the pier column bracings to be constructed.

Self Weight Factor: Specify the self-weight factor, which is calculated based on the material's unit weight and the object's volume. It is typically set to 1.