Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Excerpt
nameSIGCrossFrameCodeCheck

General

Cross Frame: Cross frame for code check

Code Check Template: The code check template is utilized to extract global parameters, results from finite element analysis, and limit states employed in the design process.

Shear Lag Factor

To perform fatigue calculations according to and tension fracture check calculations per AASHTO 9th Edition (Condition 7.2 - , Table 6.6.1.2.3-1 and 6.8.2.2), inputs for connection eccentricity and the maximum length of longitudinal welds are required. Therefore, the effective area can be determined by the formula Aeff = (1-x/L)Agwhere x represents the connection eccentricity, L is the maximum length of the longitudinal welds and Ag denotes the gross area of the section.

CrossFrameFatigue.jpgImage RemovedCrossFrameFatigue.jpgImage Added

 

These parameters, connection eccentricity (x) and maximum length of longitudinal welds (L), can be separately specified for the top chord, bottom chord, and diagonal chord.

Top Chord Connection Eccentricity: Specify the connection eccentricity (x) for top chord.

Top Chord Max Length of the Longitudinal Welds: Specify the maximum length of the longitudinal welds (L) for top chord.

Bottom Chord Connection Eccentricity: Specify the connection eccentricity (x) for bottom chord.

Bottom Chord Max Length of the Longitudinal Welds: Specify the maximum length of the longitudinal welds (L) for bottom chord.

Diagonal Chord Connection Eccentricity: Specify the connection eccentricity (x) for diagonal chord.

Diagonal Chord Max Length of the Longitudinal Welds: Specify the maximum length of the longitudinal welds (L) for diagonal chord.