Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Excerpt
nameGirder Analysis Summary Table

This component divides each span into 10 segments and reports the major axis bending moment, lateral bending moment, and shear at each location.

Girders: Select the girders for which you wish to view the results.
Factored Results: Select the load combination table that includes unfactored analysis result cases and their corresponding factors, as well as the limit states.
Ignored Insertion Points for Span Positioning: Usually, no selection is needed in this section as the span definitions are automatically determined by the object using the connected insertion points, which represent the bearing locations. However, if some of the connected insertion points are not bearings and instead represent temporary supports, they should be selected and marked as ignored.

...