Excerpt | ||
---|---|---|
| ||
GeneralCode Check Template: This parameter can be used to specify the code check template to be used for the girder’s code check. A previously defined code check template can be assigned using this parameter. Girder: Specify the girder for which the code check will be performed. Design Section w Rebars (or Tendons) [Override Section/Section from 3D]: Users can specify whether the code check will be performed according to the section that is visible in 3D or if a new section will be overridden to perform code checks accordingly. Override Design Section (Noncomposite): If the "Design Section w Rebars (or Tendons)" parameter is defined with the option "Override Section," the new section definition can be made using this parameter. The section that will override a previously defined one can be assigned from a previously defined section under Properties > Sections or can be imported. Otherwise, if the "Design Section w Rebars (Tendons)" parameter is defined with the option "Section from 3D," this parameter will not be applicable. Stages for Stress Checks:Code Check Station[ft]:
Station: This parameter can be used to specify the station at which the code check will be performed. Relative Position (readonly): The relative position of the code check station based on the total length of the girder will be presented to the user. Effective Web Width: Shear ReinforcementsShear Reinforcement Data [From 3D/User Input]: Rebar Profile: Rebar Spacing: Number of Legs: Transverse Rebar Material: |
...