Excerpt | ||
---|---|---|
| ||
InputsPier Cap: Choose the pier cap to impose the line load. Stage: Select a stage to apply the load. Start Distance From Right (relative): The relative distance where the load is applied must be specified with a value between 0 and 1, where 0 corresponds to the initial node of the selected pier cap and 1 corresponds to the final node. The initial node is defined in the direction of alignment, looking upstation (to the right in the standard view). End Distance From Right (relative): The relative distance where the load is applied must be specified with a value between 0 and 1, where 0 corresponds to the initial node of the selected pier cap and 1 corresponds to the final node. The initial node is defined in the direction of alignment, looking upstation (to the right in the standard view). Fx: Force in X direction. The longitudinal direction along the alignment will correspond to the X direction. Fy: Force in Y direction. The transverse direction along the alignment will correspond to the X direction. Fz: Force in Z direction. A positive value will apply the load in the gravity direction, while a negative value will apply the load in the opposite direction. Mx : Moment in the longitudinal direction along the PGL. My : Moment in the direction perpendicular to the PGL. Mz : Moment in the vertical direction. |