Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Excerpt
nameGirder Load

Girder Load

Girders: Girder loads can be defined based on the selected girder, construction stage, applied flange, and magnitudes in terms of forces and moments.

Girder: Select the girder to which the load will be applied.

Stage: Choose the stage at which to apply the load.

Applied Flange [Top/Bottom]:

Fx [kip/ft] : Force in the longitudinal direction along the PGL.

Fy [kip/ft] : Force in the direction perpendicular to the PGL.

Fz [kip/ft] : Force in the vertical direction. A positive value indicates a load in the global -Z or gravity direction. For usual loads (wearing surface loads - stay-in-place formwork loads), the user should input positive values.

Mx [kip-ft/ft] : Moment in the longitudinal direction along the PGL.

My [kip-ft/ft] : Moment in the direction perpendicular to the PGL.

Mz [kip-ft/ft] : Moment in the vertical direction.