Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Skew Angle: A positive skew value rotates the cross frame in a clockwise direction, while a negative skew value rotates it in a counterclockwise direction. It is important to remember that the cross frames are positioned at the specified station along a line perpendicular to the PGL, which is then rotated according to the entered skew value.

Station[Start/End]: Enter the station along the PGL. When dealing with curved girder bridges, collecting distance along the girder length can lead to different inputs for the right and left girder that are connected by cross frames, causing ambiguity. Therefore, collecting the station along the PGL is a more reliable solution to avoid such issues. Furthermore, since cross frames are typically continuous in the transverse direction, entering the same station for all cross frames ensures that their locations are consistent between each girder.

The same principle can be applied for skewed cross frames. If the user enters the same station and skew values for the cross frames between Girder 1-2, Girder 2-3, and Girder 3-4, it ensures continuity between the cross frames. It should also be noted that the cross frames are positioned along a line perpendicular to the PGL, which is rotated according to the entered skew value.

Inaccurate finite element models and disconnected nodes/elements in the cross frame can occur if the entered station values are not >= the girder start station or <= the girder end station. This can cause stability issues in the finite element model. To ensure correct station input, users should select the start/end options from the station input. This approach is especially recommended for cross frames located at the beginning or end of girders.

...

Station[Start/End]:Enter the station along the PGL. When dealing with curved girder bridges, collecting distance along the girder length can lead to different inputs for the right and left girder that are connected by cross frames, causing ambiguity. Therefore, collecting the station along the PGL is a more reliable solution to avoid such issues. Furthermore, since cross frames are typically continuous in the transverse direction, entering the same station for all cross frames ensures that their locations are consistent between each girder.

...

Horizontal Dist. btw Web Centerline and Plate Edge:

...

 

...

Stiffener

The parameters listed below are used for 3D representation. While cross-frame stiffeners do not have finite element models (FEM) and do not provide additional stiffness to the elements, they can still be applied as weight loads, depending on user-defined settings and specifications.

...