Excerpt
namePier Cap Line Load

Inputs

Pier Cap: Choose the pier cap to impose the line load.

Stage: Select a stage to apply the load.

Start Distance From Right (relative): The relative distance where the line load starts to be applied.

End Distance From Right (relative): The relative distance where the line load ends to be applied.

Fx [kip]: Force in X direction. The longitudinal direction along the alignment will correspond to the X direction.

Fy [kip]: Force in Y direction. The transverse direction along the alignment will correspond to the X direction.

Fz [kip]: Force in Z direction. A positive value will apply the load in the gravity direction, while a negative value will apply the load in the opposite direction.

Mx [kip-ft]:

My [kip-ft]:

Mz [kip-ft]: