Excerpt | ||
---|---|---|
| ||
InputsPier Cap: Choose the pier cap to impose the line load. Stage: Select a stage to apply the load. Start Distance From Right (relative): The relative distance where the line load starts to be applied. End Distance From Right (relative): The relative distance where the line load ends to be applied. Fx [kip]: Force in X direction. The longitudinal direction along the alignment will correspond to the X direction. Fy [kip]: Force in Y direction. The transverse direction along the alignment will correspond to the X direction. Fz [kip]: Force in Z direction. A positive value will apply the load in the gravity direction, while a negative value will apply the load in the opposite direction. Mx [kip-ft]: My [kip-ft]: Mz [kip-ft]: |