Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor#DEEBFF

Follow the next steps to create pier cap code check.

...

Go to Substructure Code Checks/Pier Cap Code Check.

...

Set PierCapCCT to Code Check Template.

...

Name the 1st row PierCapCC.

...

To set “Section”, click on three-dots icon and Select.

...

...

From drop-down menu, select pier cap section.

...

Input reinforcement data as:

...

Tip

Pier cap code check is completed.

...

Go to Pier Cap Code Check under Superstructure Code Checks on the tree view.

...

Copy General from model inputs and paste into OpenBrIM.

...

Info

After clicking on ‘Substructure Code Checks> Pier Cap Code Check' in the navigation treeview, follow the steps to define the Pier Cap Code Check. You can use the collapsed documentation page below for more information on the explanations of each parameter.

Expand
titlePier Cap Code Check
Pier Cap Code Check [SIG]
1

(blue star) Click the three-dots icon on the Pier Cap cell, and then set PierCap1.

Image Added
2

As a result of these operations, an issue will appear on the OpenBrIM screen. This does not necessarily mean that any operation was done incorrectly. The issue will be resolved when the code check template, pier cap section, transverse reinforcement profile, and shear reinforcement profile are defined in the next step.

Image Added
3

Insert excerpt
_Quick Tips
_Quick Tips
nameIssue
nopaneltrue

4

(blue star) Click the three-dots icon on the Code Check Template cell, and then set PierCapCCT.

Image Added
5

(blue star) Keep the Section Generation Method as default.

Image Added
6

(blue star) Click three-dots icon on Section cell and select a Section as PierCapRec_Mid.

If you have reached this stage and you don't have a section to select, and if you want to use the Import Button, you can refer to the Quick Tip.

Image AddedImage AddedImage Added
7

Insert excerpt
_Quick Tips
_Quick Tips
nameImportSection
nopaneltrue

8

(blue star) Click the three-dots icon on the Transverse Reinforcement Profile cell, and then set ASTMA615No5.

Image Added
9

(blue star) Click the three-dots icon on the Shear Reinforcement Material cell, and then set A615_60.

Image Added
10

(blue star) Enter the Spacing of the transverse reinforcement as 6.

Image Added
11

(blue star) Enter the No. of Legs of Transverse Reinforcement as 2.

Image Added
12

(blue star) Enter the Station of Section from Right End as 10.

Image Added

13

(blue star) Keep the Check for as default.

Image Added
14

(blue star) Set name as PierCapCC.

Image Added
15

To model all the pier cap code check, copy the data below and paste the parameters into the first cell in OpenBrIM spreadsheet. Refer to the quick tip for an easy guide on how to perform the copy operation. After completing the copy, proceed to the next step to verify the model.

Insert excerpt
_Quick Tips
_Quick Tips
nameCopyPasteInputs
nopaneltrue

Pier Cap Code Check

General

Code Block
PierCapCC	PierCapCCT	PierCap1	User Input	PierCapRec_Mid	ASTMA615No5	A615_60	6.0000	2.0000	10.0000	All
PCCC1	PierCapCCT2	PierCap1	User Input	PierCapRec_Mid	ASTMA615No5	A615_60	6.0000	2.0000	10.0000	All

Anchor
Photo
Photo

Tip

The completed pier cap code checks are illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips.

...

Tip

To view the entire procedure explained on this page, please watch the recorded Video below.