Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Follow the next steps to specify the load cases (classes) combined with the load factors. |
...
Go to Combinations/Design Load Combinations/Limit States one last time and select Load Cases 1.
...
Click on three-dots icon under DC1 column of StrengthI limit state and click Select.
...
Select DC1 (Remember, its content was composed of the corresponding construction stages in Combinations/Result Extraction Cases step).
...
...
In same way, keep selecting the load cases for the corresponding limit states.
...
Load cases not included in this example should remain as NULL.
Tip |
---|
Serviceability limit states (Strength, Service, and Fatigue) and load combinations are completed. |
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Follow the next steps to include a unique load combination for the constructability limit state. |
...
Under Combinations/Design Load Combinations/Limit States, add a row named StrIConst.
...
Select DC1 and keep the rest of the load cases as NULL.
...
Enter γmax as 1.4.
...
Go to Combinations/Design Load Combinations/Load Combination Table one last time.
...
...
Add a row named SuperStrConstLCT.
...
Select StrengthI column as StrIConst, and keep the rest of the limit states as NULL.
Tip |
---|
Analysis loads & combinations of the code checks are completed. |
...
Go to Limit States under Design Load Combinations on the tree view.
...
Copy Load Modifiers, Load Cases 1, Load Cases 2, and Load Cases 3 from model inputs and paste into OpenBrIM.
...
Limit States
...
Load Modifiers
Code Block |
---|
StrengthI 1.0000 1.0000 1.0000
StrengthIII 1.0000 1.0000 1.0000
StrengthV 1.0000 1.0000 1.0000
ServiceI 1.0000 1.0000 1.0000
ServiceII 1.0000 1.0000 1.0000
FatigueI 1.0000 1.0000 1.0000
FatigueII 1.0000 1.0000 1.0000
StrengthII 1.0000 1.0000 1.0000
StrengthIV 1.0000 1.0000 1.0000
ServiceIII 1.0000 1.0000 1.0000
ServiceIV 1.0000 1.0000 1.0000
StrIConst 1.0000 1.0000 1.0000 |
...
Load Cases 1
Code Block |
---|
StrengthI DC1 1.2500 0.9000 DC2 1.2500 0.9000 DW 1.5000 0.6500 LL 1.7500 1.7500 BR 1.7500 1.7500 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 1.7500 1.7500 NULL 1.0000 1.0000
StrengthIII DC1 1.2500 0.9000 DC2 1.2500 0.9000 DW 1.5000 0.6500 LL 0.0000 0.0000 BR 0.0000 0.0000 WS 1.0000 1.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 0.0000 0.0000 NULL 1.0000 1.0000
StrengthV DC1 1.2500 0.9000 DC2 1.2500 0.9000 DW 1.5000 0.6500 LL 1.3500 1.3500 BR 1.3500 1.3500 WS 1.0000 1.0000 WL 1.0000 1.0000 TU 1.2000 0.5000 CENT 1.3500 1.3500 NULL 1.0000 1.0000
ServiceI DC1 1.0000 1.0000 DC2 1.0000 1.0000 DW 1.0000 1.0000 LL 1.0000 1.0000 BR 1.0000 1.0000 WS 1.0000 1.0000 WL 1.0000 1.0000 TU 1.2000 0.5000 CENT 1.0000 1.0000 NULL 1.0000 1.0000
ServiceII DC1 1.0000 1.0000 DC2 1.0000 1.0000 DW 1.0000 1.0000 LL 1.3000 1.3000 BR 1.3000 1.3000 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 1.3000 1.3000 NULL 1.0000 1.0000
FatigueI DC1 0.0000 0.0000 DC2 0.0000 0.0000 DW 0.0000 0.0000 LLFat 1.7500 1.7500 BR 1.7500 1.7500 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 0.0000 0.0000 CENT 1.7500 1.7500 NULL 1.0000 1.0000
FatigueII DC1 0.0000 0.0000 DC2 0.0000 0.0000 DW 0.0000 0.0000 LLFat 0.8000 0.8000 BR 0.8000 0.8000 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 0.0000 0.0000 CENT 0.8000 0.8000 NULL 1.0000 1.0000
StrengthII DC1 1.2500 0.9000 DC2 1.2500 0.9000 DW 1.5000 0.6500 LL 1.3500 1.3500 BR 1.3500 1.3500 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 1.3500 1.3500 NULL 1.0000 1.0000
StrengthIV DC1 1.5000 0.9000 DC2 1.5000 0.9000 DW 1.5000 0.6500 LL 0.0000 0.0000 BR 0.0000 0.0000 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 0.0000 0.0000 NULL 1.0000 1.0000
ServiceIII DC1 1.0000 1.0000 DC2 1.0000 1.0000 DW 1.0000 1.0000 LL 1.0000 1.0000 BR 1.0000 1.0000 WS 0.0000 0.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 1.0000 1.0000 NULL 1.0000 1.0000
ServiceIV DC1 1.0000 1.0000 DC2 1.0000 1.0000 DW 1.0000 1.0000 LL 0.0000 0.0000 BR 0.0000 0.0000 WS 1.0000 1.0000 WL 0.0000 0.0000 TU 1.2000 0.5000 CENT 0.0000 0.0000 NULL 1.0000 1.0000
StrIConst DC1 1.4000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 WL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 |
...
Load Cases 2
Code Block |
---|
StrengthI NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.7500 1.7500 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.7500 1.7500
StrengthIII NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000
StrengthV NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.3500 1.3500 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.3500 1.3500
ServiceI NULL 1.2000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.5000 0.5000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.0000 1.0000
ServiceII NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.3000 1.3000 NULL 0.5000 0.5000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.3000 1.3000
FatigueI NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.7500 1.7500 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.7500 1.7500
FatigueII NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.8000 0.8000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.8000 0.8000
StrengthII NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.3500 1.3500 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.3500 1.3500
StrengthIV NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000
ServiceIII NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.5000 0.5000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 1.0000 1.0000
ServiceIV NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000 NULL 0.0000 0.0000
StrIConst NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 NULL 1.0000 1.0000 |
Load Cases 3
...
Info |
---|
After clicking on ‘Combinations> Design Load Combinations> Limit States' in the navigation treeview, follow the steps to define the Limit State. You can use the collapsed documentation page below for more information on the explanations of each parameter. |
Expand | ||
---|---|---|
| ||
Limit States [SIG] |
1 |
| |
2 |
| |
3 |
| |
4 |
| |
5 | DC2, DW, LL, BR, WS, WL, TU and CE parameters can be defined similarly to DC1. | |
6 |
| |
7 |
| |
8 | Proceed to the next step to verify the model. |
Anchor | ||||
---|---|---|---|---|
|
Tip |
---|
The completed limit states are illustrated below. Please verify that you have the same model on your end by examining each view provided here. For more information on how to perform visual checks, refer to the quick tips. |
...
Tip |
---|
To view the entire procedure explained on this page, please watch the recorded Video below. |
...