Skew Angle [deg]: A positive skew value rotates the cross frame in a clockwise direction, while a negative skew value rotates it in a counterclockwise direction. It is important to remember that the cross frames are positioned at the specified station along a line perpendicular to the PGL, which is then rotated according to the entered skew value.
...
Station [ft][Start/End]: Enter the station along the PGL. When dealing with curved girder bridges, collecting distance along the girder length can lead to different inputs for the right and left girder that are connected by cross frames, causing ambiguity. Therefore, collecting the station along the PGL is a more reliable solution to avoid such issues. Furthermore, since cross frames are typically continuous in the transverse direction, entering the same station for all cross frames ensures that their locations are consistent between each girder.
...
Inaccurate finite element models and disconnected nodes/elements in the cross frame can occur if the entered station values are not >= the girder start station or <= the girder end station. This can cause stability issues in the finite element model. To ensure correct station input, users should select the start/end options from the station input. This approach is especially recommended for cross frames located at the beginning or end of girders.
...
Sections
Top Chord Section - Bottom Chord Section - Diagonal Chord Section:
...