Additional Haunch Width [in]: The additional haunch width is measured from both the right and left extensions of the top flange. During deck construction, the automatic haunch load computation is impacted by both the haunch thickness and additional haunch width.

Top Flange Material - Web Material - Bottom Flange Material: Hybrid girders are supported, allowing the assignment of different materials to the top flange, bottom flange, and web. Furthermore, it is possible to use varying steel materials between different stations through station-dependent material definitions.

...