bgColor#DEEBFF

Follow the next steps to set boundary conditions for each bearing location (insertion point) that you have defined while creating the bridge layout.

1

Go to Bearing Fixity on the tree view next to data spreadsheet.

2

Set Tx/Ty/Tz/Rx/Ry/Rz.

3

Set Transfer Force to Substructure as Yes for interior pier locations.

4

Set Transfer Force to Substructure as No for start and end support locations.

5
Expand
titleQuick Tip

In this part, dofs are assigned to nodes. The coordinate system of the each insertion point changes along the support line and alignment. According to this new coordinate system, new dofs should be assigned.

Tx/Ty/Tz/Rx/Ry/Rz fixities are shown below.

Image Added

Bearing Rotation parameter rotates the support clockwise along the -Z of the insertion point.

Image Added

FE behaviour of Transfer Force to Substructure.

...

Insert excerpt
_ConfluenceInclusions
_ConfluenceInclusions
nameCopyPaste
nopaneltrue

...